Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome)

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain.

Abstract
Background: Displaced mid shaft clavicular fracture can be manage conservatively and surgically, open reduction and internal fixation with plate and screw, as primary intervention is valid option.
Method: prospective cohort study was conducted of 18 young patients with displaced mid shaft clavicle fracture ,these patients underwent open reduction and plate and screw fixation, after 6 months follow up evaluation done for complication rates functional score by DASH & ULCA score, patients satisfactions and estimation of time need for resume job.
Results: 15/18 patients were male; those patients underwent open reduction and internal fixation by plate and screw in time up to 40 days post injury. 50% have complications mostly minor complications like prominent hard ware and scar or paresthesia, 2/18 patients have major complication, one infection and other implant failure ,most of patients 14/18 have fully satisfied with result ,61% resumed the job early within 3 weeks. The mean DASH score was 34.9 ,ULCA score 28.9, factors effecting DASH score was comorbidity, complication, range of motion, satisfaction and time to return to job, while ULCA score effected by use of regional anesthesia, complication, range of motion, satisfaction and time to return to job. There is no statistical relationship between age, gender, and complications and time to fixation to satisfaction or time to resume job.
Conclusion: open reduction and internal fixation of displaced mid shaft clavicle fracture should be offered for patient with expectation of good outcome especially with supervised rehabilitation.

Key words: Displaced, mid shaft clavicular fracture, fixation, plate and screws, functional outcome.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Ahmed Nama M. Altaei
Articles by Mustafa Waleed yahya
Articles by Rafiq Qutran Al-Hussain
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33


Web Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). http://www.ejmcm.com/?mno=134815 [Access: October 13, 2020]. doi:https://doi.org/10.31838/ejmcm.07.02.33


AMA (American Medical Association) Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33



Vancouver/ICMJE Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33



Harvard Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain (2020) Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33



Turabian Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. 2020. Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33



Chicago Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. "Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome)." doi:https://doi.org/10.31838/ejmcm.07.02.33



MLA (The Modern Language Association) Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain. "Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome)." doi:https://doi.org/10.31838/ejmcm.07.02.33



APA (American Psychological Association) Style

Ahmed Nama M. Altaei, Mustafa Waleed yahya, Rafiq Qutran Al-Hussain (2020) Displaced Mid Shaft Clavicular Fracture Fixation by Plate and Screws (Functional Outcome). doi:https://doi.org/10.31838/ejmcm.07.02.33








AUTHOR LOGIN

REVIEWER LOGIN

Indexed
&
Abstracted


Journal is indexed by the following services:

Scopus
CrossRef
JISC KB+
SHERPA RoMEO
Cengage Learning
Directory of Open Access Journals (DOAJ)
Google Scholar

In addition, all journals are available for harvesting via OAI-PMH.


ABOUT JOURNAL
POLICIES
STATEMENTS

This is an open access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the Budapest Open Access Initiative (BOAI) definition of open access.

The articles in European Journal of Molecular & Clinical Medicine are open access articles licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-sa/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.