• Register
  • Login

European Journal of Molecular & Clinical Medicine

  • Home
  • Browse
    • Current Issue
    • By Issue
    • By Subject
    • Keyword Index
    • Author Index
    • Indexing Databases XML
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Indexing and Abstracting
    • Peer Review Process
    • News
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
Advanced Search

Notice

As part of Open Journals’ initiatives, we create website for scholarly open access journals. If you are responsible for this journal and would like to know more about how to use the editorial system, please visit our website at https://ejournalplus.com or
send us an email to info@ejournalplus.com

We will contact you soon

  1. Home
  2. Volume 8, Issue 3
  3. Authors

Online ISSN: 2515-8260

Volume8, Issue3

The effect on CT size-specific dose estimates of mis-positioning patientsfrom the iso-centre

    Arif Jauhari Choirul Anam Mohd Hanafi Ali William Ian Duncombe Rae Siti Akbari Tina Meilinda

European Journal of Molecular & Clinical Medicine, 2021, Volume 8, Issue 3, Pages 155-164

  • Show Article
  • Download
  • Cite
  • Statistics
  • Share

Abstract

This study evaluates the effect of mis-positioning of patients in relation to the iso-centre in CT examinations on the dose received by phantoms with various diameters. Phantoms with water-equivalent diameters (Dw) ranging from 8.5 cm to 42.1 cm were scanned using a GE Optima CT scanner with exposure factors as follows: 200 mA, 120 kVp, 1.375 Pitch, 50 cm field of view (FOV), 5 mm beam collimation, and 1 s rotation time. Doses were measured using the CT dose profiler (RTI Electronics). After obtaining doses in every hole of the phantoms, weighted doses were computed. It is found that the dose decreased with an increase in the Dw. The ratio of the doses when positioned off-centre by 2 cm and 4 cm with respect to the iso-centre have p-values of 0.914 and 0.919, which shows no significant difference (p> 0.05).
Keywords:
    Computed Tomography CT dose CTDIvol SSDE mis-positioning
  • PDF (498 K)
  • XML
(2021). The effect on CT size-specific dose estimates of mis-positioning patientsfrom the iso-centre. European Journal of Molecular & Clinical Medicine, 8(3), 155-164.
Arif Jauhari; Choirul Anam; Mohd Hanafi Ali; William Ian Duncombe Rae; Siti Akbari; Tina Meilinda. "The effect on CT size-specific dose estimates of mis-positioning patientsfrom the iso-centre". European Journal of Molecular & Clinical Medicine, 8, 3, 2021, 155-164.
(2021). 'The effect on CT size-specific dose estimates of mis-positioning patientsfrom the iso-centre', European Journal of Molecular & Clinical Medicine, 8(3), pp. 155-164.
The effect on CT size-specific dose estimates of mis-positioning patientsfrom the iso-centre. European Journal of Molecular & Clinical Medicine, 2021; 8(3): 155-164.
  • RIS
  • EndNote
  • BibTeX
  • APA
  • MLA
  • Harvard
  • Vancouver
  • Article View: 382
  • PDF Download: 501
  • LinkedIn
  • Twitter
  • Facebook
  • Google
  • Telegram
Journal Information

Publisher:

Email:  editor.ejmcm21@gmail.com

  • Home
  • Glossary
  • News
  • Aims and Scope
  • Privacy Policy
  • Sitemap

 

For Special Issue Proposal : editor.ejmcm21@gmail.com

This journal is licensed under a Creative Commons Attribution 4.0 International (CC-BY 4.0)

Powered by eJournalPlus